Substance · official US FDA label
Monoxyde d'azote (nitric oxide)
8 medicines listed on Vimpia contain it, alone or combined. Below, the official US FDA label for nitric oxide, unchanged.
Want to buy it?
Trouver shows the pharmacies near you that have it right now, and their prices. The reservation pages are in French.
This is a US label.
The official US FDA label for nitric oxide, effective April 20, 2026, describes products sold in the United States. The medicine sold in DR Congo may differ in strength, form or approved uses: ask a pharmacist or a doctor.
Official US FDA label for nitric oxide
Data provided by the U.S. Food and Drug Administration (openFDA), unchanged. The full label on DailyMed.
Uses
INDICATIONS AND USAGE Noxivent ™ is a vasodilator indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents.
1. INDICATIONS AND USAGE Noxivent™ is indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents.
Dosage
US dosage, for products sold in the United States. For a medicine bought in DR Congo, follow its box, its leaflet or your pharmacist.
DOSAGE AND ADMINISTRATION The recommended dose is 20 ppm, maintained for up to 14 days or until the underlying oxygen desaturation has resolved ( 2.1 ). Doses greater than 20 ppm are not recommended ( 2.1 , 5.2 ) Administration: • Avoid abrupt discontinuation ( 2.2 , 5.1 ).
2. DOSAGE AND ADMINISTRATION
2.1 Dosage Term and near-term neonates with hypoxic respiratory failure The recommended dose of Noxivent™ is 20 ppm. Maintain treatment up to 14 days or until the underlying oxygen desaturation has resolved and the neonate is ready to be weaned from Noxivent™ therapy. Doses greater than 20 ppm are not recommended [see Warnings and Precautions (5.2) ].
2.2 Administration Nitric Oxide Delivery Systems Noxivent™ must be administered using a calibrated FDA-cleared Nitric Oxide Delivery System (NODS). There are various FDA-cleared NODS; refer to the NODS labeling to determine which NODS to use with this drug product and for needed information on training and technical support for users of this drug product with the NODS. Do not use Noxivent with Inomax DSIR Plus and DSIR MRI NODS. Do not use Noxivent in the MRI suite. Keep available a backup battery power supply and an independent reserve nitric oxide delivery system to address power and system failures. Monitoring Measure methemoglobin within 4-8 hours after initiation of treatment with Noxivent™ and periodically throughout treatment [see Warnings and Precautions (5.2 )]. Monitor for PaO 2 and inspired NO 2 during Noxivent™ administration [see Warnings and Precautions 5.3 )]. Weaning and Discontinuation Avoid abrupt discontinuation of Noxivent™ [see Warnings and Precautions (5.1 )]. To wean Noxivent™, downtitrate in several steps, pausing several hours at each step to monitor for hypoxemia.
Warnings and precautions
WARNINGS AND PRECAUTIONS Rebound: Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure ( 5.1 ). Methemoglobinemia: Methemoglobin increases with the dose of nitric oxide; following discontinuation or reduction of nitric oxide, methemoglobin levels return to baseline over a period of hours ( 5.2 ). Elevated NO 2 Levels: Monitor NO 2 levels ( 5.3 ). Heart Failure: In patients with pre-existing left ventricular dysfunction, Noxivent™ may increase pulmonary capillary wedge pressure leading to pulmonary edema ( 5.4 ).
5. WARNINGS AND PRECAUTIONS
5.1 Rebound Pulmonary Hypertension Syndrome following Abrupt Discontinuation Wean from Noxivent™ [see Dosage and Administration (2.2 )]. Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure, i.e., Rebound Pulmonary Hypertension Syndrome. Signs and symptoms of Rebound Pulmonary Hypertension Syndrome include hypoxemia, systemic hypotension, bradycardia, and decreased cardiac output. If Rebound Pulmonary Hypertension occurs, reinstate Noxivent™ therapy immediately.
5.2 Hypoxemia from Methemoglobinemia Nitric oxide combines with hemoglobin to form methemoglobin, which does not transport oxygen. Methemoglobin levels increase with the dose of Noxivent™; it can take 8 hours or more before steady-state methemoglobin levels are attained. Monitor methemoglobin and adjust the dose of Noxivent™ to optimize oxygenation. If methemoglobin levels do not resolve with decrease in dose or discontinuation of Noxivent™, additional therapy may be warranted to treat methemoglobinemia [see Overdosage (10 )].
5.3 Airway Injury from Nitrogen Dioxide Nitrogen dioxide (NO 2 ) forms in gas mixtures containing NO and O 2 . Nitrogen dioxide may cause airway inflammation and damage to lung tissues. If there is an unexpected change in NO 2 concentration, or if the NO 2 concentration reaches 3 ppm when measured in the breathing circuit, then the delivery system should be assessed in accordance with the Nitric Oxide Delivery System O&M Manual troubleshooting section, and the NO 2 analyzer should be recalibrated. The dose of Noxivent™ and/or FiO 2 should be adjusted as appropriate.
5.4 Worsening Heart Failure Patients with left ventricular dysfunction treated with Noxivent™ may experience pulmonary edema, increased pulmonary capillary wedge pressure, worsening of left ventricular dysfunction, systemic hypotension, bradycardia and cardiac arrest. Discontinue Noxivent™ while providing symptomatic care.
Side effects
ADVERSE REACTIONS The most common adverse reaction is hypotension. ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact contact Vero Biotech at 1-833-669-8368 and http://www.vero-biotech.com/ or FDA at 1-800-FDA-1088 or or www.fda.gov/medwatch .
6. ADVERSE REACTIONS The following adverse reactions are discussed elsewhere in the label; Hypoxemia [see Warnings and Precautions (5.2 )] Worsening Heart Failure [see Warnings and Precautions (5.4 )]
6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The adverse reaction information from the clinical studies does, however, provide a basis for identifying the adverse events that appear to be related to drug use and for approximating rates. Controlled studies have included 325 patients on nitric oxide doses of 5 to 80 ppm and 251 patients on placebo. Total mortality in the pooled trials was 11% on placebo and 9% on nitric oxide, a result adequate to exclude nitric oxide mortality being more than 40% worse than placebo. In both the NINOS and CINRGI studies, the duration of hospitalization was similar in nitric oxide and placebo-treated groups. From all controlled studies, at least 6 months of follow-up is available for 278 patients who received nitric oxide and 212 patients who received placebo. Among these patients, there was no evidence of an adverse effect of treatment on the need for rehospitalization, special medical services, pulmonary disease, or neurological sequelae. In the NINOS study, treatment groups were similar with respect to the incidence and severity of intracranial hemorrhage, Grade IV hemorrhage, periventricular leukomalacia, cerebral infarction, seizures requiring anticonvulsant therapy, pulmonary hemorrhage, or gastrointestinal hemorrhage. In CINRGI, the only adverse reaction (>2% higher incidence on nitric oxide than on placebo) was hypotension (14% vs. 11%).
6.2 Post-Marketing Experience Post marketing reports of accidental exposure to nitric oxide for inhalation in hospital staff has been associated with chest discomfort, dizziness, dry throat, dyspnea, and headache.
Medicines that contain it
Names as they are sold. A medicine without an English page links to its French page.
- KINOX 225 ppm mole/mole, gaz médicinal comprimé
- KINOX 450 ppm mole/mole, gaz médicinal comprimé
- KINOX 800 ppm mole/mole, gaz médicinal comprimé
- MONOXYDE D'AZOTE MESSER 800 PPM (V/V), gaz médicinal comprimé
- MONOXYDE D’AZOTE SOL FRANCE 250 ppm mole/mole, gaz médicinal comprimé
- MONOXYDE D’AZOTE SOL FRANCE 800 ppm mole/mole, gaz médicinal comprimé
- NOXAP 200 ppm mole/mole, gaz médicinal comprimé
- NOXAP 800 ppm mole/mole, gaz médicinal comprimé
Sources
- ●Labels: U.S. Food and Drug Administration, openFDA (public domain). Data provided by the U.S. Food and Drug Administration (openFDA), unchanged. DailyMed.
- ●English names of substances: RxNorm, U.S. National Library of Medicine.
- ●Marketing authorizations: register of the ACOREP, DR Congo.
- ●Essential medicines: national list of essential medicines of DR Congo (LNME).
- ●Composition: public medicines database of France (BDPM), ANSM, open licence.
Public information, for reference only: it does not replace the advice of a pharmacist or a doctor. Vimpia writes nothing about how to use a medicine and translates nothing: the label is the US FDA's, unchanged; names, composition and authorizations come from the official sources above.